logo
Thuis > producten > ultrasone stroommeter >
FLOWSIC100 Flare-XT ultrasonic flow measurement instrument

FLOWSIC100 Flare-XT ultrasonic flow measurement instrument

FLOWSIC100 ultrasonic flow meter

Flare-XT flow measurement instrument

ultrasonic flow meter with warranty

Plaats van herkomst:

Zwitserland

Merknaam:

Endress+Hauser

Certificering:

CE

Modelnummer:

FLOWSIC100

Neem contact met ons op
Vraag een offerte
Productgegevens
Het meten van principe:
Ultrasone transittijdverschilmeting
Gemeten variabelen:
Massastroomsnelheid, volumestroom sc (standaardtoestand), volumestroom ac (werkelijke toestand), mol
Meetbereik:
0,03 m/s ... 120 m/s (0,1 ft/s ... 394 ft/s)
Nominale buismaat:
1-pad meting 4″ ... 86″
Digitale Mededeling:
In een deksel
Markeren:

FLOWSIC100 ultrasonic flow meter

,

Flare-XT flow measurement instrument

,

ultrasonic flow meter with warranty

Betaling en verzendvoorwaarden
Min. bestelaantal
1 stks
Verpakking Details
Elke eenheid heeft een individuele doos en alle dozen zijn verpakt in standaardpakketten of beschikb
Levertijd
5-8 WERKDAGEN
Betalingscondities
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Levering vermogen
1000 stuk/stukken per week bespreekbaar
Productbeschrijving
FLOWSIC100 Flare-XT Ultrasonic Flow Measurement Instrument
Advanced ultrasonic flow measurement instrument designed for demanding industrial applications including flare gas measurement, steam flow monitoring, and process optimization.
Key Specifications
Measured Variables Mass flow rate, volumetric flow (standard condition), volumetric flow (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity
Measuring Range 0.03 m/s ... 120 m/s (0.1 ft/s ... 394 ft/s)
Conformities ATEX: 2014/34/EU, EMC: 2014/30/EU, RoHS: 2011/65/EU, PED: 2014/68/EU
Applications
  • Detection of flare gas leaks and steam flow measurement
  • Monitoring of gas losses and steam injection in flare gas burning
  • Process optimization and predictive maintenance
  • Flare gas measurement for natural gas production and processing
  • Flare gas measurement in chemical and petrochemical plants
  • Measurement of LNG boil-off gas
Device Features
  • Reliable measurement at high gas velocities and changing gas compositions
  • Direct mass flow calculation without additional gas analyzers
  • Intuitive FLOWgate™ software for commissioning, operation and diagnostics
  • Self-monitoring, self-testing and predictive maintenance capabilities
Key Benefits
  • Compliance with multiple standards and guidelines for flare gas measurement
  • Maximum plant availability and operational reliability
  • Compatibility with current and future communication architectures
  • Independent maintenance with verification on demand
  • Easy replacement of existing measurement systems with retrofit solutions
Technical Details
Measuring Principle Ultrasonic transit time difference measurement
Max. Measurement Error Volumetric flow, a.c.: 1% ... 5% (≥ 0.3 m/s)
Mass flow rate a.c.: 2% ... 5.5% (≥ 0.3 m/s)
With spool piece and flow calibration: 0.5% ... 2%
Medium Temperature Range -196 °C ... +280 °C (-320 °F ... +536 °F)
Operating Pressure Range Up to 20 bar(g) depending on device flange and certification
Nominal Pipe Size 1-path: 4″ ... 86″, 2-path: 12″ ... 86″
Hazardous Area Approvals
Comprehensive certifications for Interface Unit and Sensors including IECEx, ATEX, and NEC/CEC approvals for Zone 1, Zone 2, and Division 1/2 applications with various gas groups and temperature classes.
Outputs & Communication
Analog Outputs Up to 6 outputs (16-bit, 4-20 mA), galvanically isolated, NAMUR NE43 compliant
Digital Outputs Switching outputs (70 mA max) and frequency outputs (10 kHz max)
Digital Communication HART, MODBUS, FOUNDATION FIELDBUS

Stuur uw vraag rechtstreeks naar ons